-40%

DATAKOM DKG-329 Generator /Mains Automatic Transfer Switch Control Panel / ATS

$ 165.25

Availability: 62 in stock
  • Brand: Datakom
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Item must be returned within: 30 Days
  • MPN: Does Not Apply
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Condition: New

    Description

    WE DO NOT SELL THIS PRODUCT TO USA AND CANADA
    DESCRIPTION
    The Datakom DKG-329 is a control and protection panel designed to monitor 3-phase mains voltages, send remote start command to generating sets and make changeover of both generator and mains contactors.
    The unit offers an internal synchroscope for uninterrupted transfer in both directions. The number of gensets to run before transfer is selectable, allowing multiple genset support. In AUTOMATIC position, the unit monitors mains phase voltages. In case of a mains failure it controls the remote starting and load transfer of the generating set, and once the generator is running, it monitors internal protections and external fault inputs. If a fault condition occurs, the unit disables the remote starting automatically and indicates the failure source with the corresponding led lamp and text. The unit provides a comprehensive set of digitally adjustable program parameters. The unauthorized access to program parameters is prevented by a 3 level password system.
    All programs may be modified via front panel pushbuttons and do not require any external unit. Fault conditions are considered in 3 categories as Warnings, Loaddumps and Shutdown Alarms. Measured values have separate programmable limits for warning and shutdown conditions.
    The unit is able to initiate modem calls and sending SMS messages in fault conditions. Last 100 faults are stored in the event log file. The event log includes not only the date-time information, but also a comprehensive list of measured parameters at the time that the fault has occurred. The service request indicator lamp turns on at the expiration of either engine hours or time limits. It is possible to monitor and control the operation of the system locally or remotely with the WINDOWS based RAINBOW program. The unit supports MODBUS protocol enabling communication with PLCs and building management systems. The MODBUS protocol is also supported through GSM and PSTN modems.
    The unit is designed for front panel mounting. Connections are made with 2 part plug and socket connectors.
    The unit offers triple language support. Default languages are English-Turkish and Chinese. Please contact Datakom for other available languages.
    MEASUREMENTS
    Generator Volts: L1-N, L2-N, L3-N
    Generator Volts: L1-L2, L2-L3, L3-L1
    Generator Frequency
    Mains Volts: L1-N, L2-N, L3-N
    Mains Volts: L1-L2, L2-L3, L3-L1
    Mains Frequency
    Load Amps: L1, L2, L3
    Load kW: L1, L2, L3, total
    Load kVAr: L1, L2, L3
    Load pf: L1, L2, L3, total
    Synchroscope Phase Angle
    Battery Voltage
    STATISTICS
    Following incremental counters provide statistics about past performance of the generating set:
    Engine Hours Run
    Total KW-h
    Engine Hours to Service
    Time to Service
    EVENT LOGGING
    The unit records last 100 events with date-time stamp and a total of 14 measured parameters. Recorded events are:
    shutdown alarms, loaddumps and warnings
    periodic records
    WEEKLY OPERATION SCHEDULE
    In AUTO mode only, the unit offers the capability of defining a weekly operation schedule. Programmable parameters allow the genset to operate automatically only in defined time limits of each weekday.
    The internal battery backed-up real time clock allows precise switching times.
    DIGITAL INPUTS
    The unit has 7 configurable digital inputs. Each input has following programmable parameters:
    alarm type: shutdown / load_dump / warning / no alarm
    alarm polling: on engine running / always / on mains OK
    latching / non-latching operation,
    contact type: NO / NC
    switching: BAT+ / BAT-
    DIGITAL OUTPUTS
    The unit provides 6 digital outputs and 2 of them have programmable functions, selectable from a list. Any function or alarm condition may be output as a relay output. Using two Relay Expansion Modules, the number of relays may be increased to 22, 16 of them being volt-free contacts.
    TELEMETRY AND REMOTE PROGRAMMING
    The unit provides the user with large telemetry facilities via its standard RS-232 serial port, connecting either to a PC, PLC or a GSM or PSTN modem. It supports both RAINBOW and MODBUS communication protocols. The standard PC software offers local and modem operation capabilities as well as modem networking feature.
    The PC program is used for below purposes:
    parameter upload/download
    remote monitoring and control
    diagnostics and analysis
    The MODBUS interface allows the unit to be integrated in building management systems.
    TECHNICAL SPECIFICATIONS
    Alternator voltage:
    0 to 300 V-AC (Ph-N)
    Alternator frequency:
    0-100 Hz.
    Mains voltage:
    0 to 300 V-AC (Ph-N)
    Mains frequency:
    0-100 Hz.
    DC Supply Range:
    9.0 to 30.0 V-DC
    Cranking dropouts:
    survives 0 V for 100ms.
    Typical Standby Current:
    100 mA-DC
    Maximum Operating Current:
    200 mA-DC (Relay outputs open)
    Generator/Mains Contactor Relay Outputs:
    16 A / 250V
    DC Outputs:
    1A @ 28V
    Current inputs:
    from CTs, .../5A. Max load 0.7VA per phase.
    Serial port:
    RS-232, 9600 bauds, no parity, 1 bit stop
    Operating temp.:
    -20°C (-4°F) to 70 °C (158°F).
    Storage temp.:
    -40°C (-40°F) to 80 °C (176°F).
    Maximum humidity:
    95% non-condensing.
    Dimensions:
    165 x 125 x 48 mm (WxHxD)
    Panel Cut-out Dimensions:
    151x111 mm minimum.
    Weight:
    300 g (approx.)
    Case Material:
    High Temperature ABS/PC (UL94-V0)
    IP Protection:
    IP65 from front panel, IP30 from the rear
    Conformity (EU directives)
    2006/95/EC (low voltage)
    2004/108/EC (electro-magnetic compatibility)
    Norms of reference:
    EN 61010 (safety requirements)
    EN 61326 (EMC requirements)
    ---------------------------------------------------------------------------------------------------------------
    Check our contactor pairs for this controller here:
    ELPRO CEM-40 Contactor Pair, 3P 40A 120/208V
    ELPRO CEM-40 Contactor Pair/Set, 3P 40A 120/208V 60Hz with interlocking
    ELPRO CEM-40 Contactor Pair, 3P 40A 230/400V
    ELPRO CEM-40 Contactor Pair/Set, 3P 40A 230/400V 50Hz with interlocking
    ELPRO CEM-65 Contactor Pair, 3P 65A 120/208V
    ELPRO CEM-65 Contactor Pair/Set, 3P 65A 120/208V 60Hz with interlocking
    ELPRO CEM-65 Contactor Pair, 3P 65A 230/400V
    ELPRO CEM-65 Contactor Pair/Set, 3P 65A 230/400V 50Hz with interlocking
    Visit my eBay Store:
    Datakom-controllers4generators
    ---------------------------------------------------------------------------------------------------------------
    Check out
    my
    other items
    for generator sets:
    J1939 Communication Units
    Synchronization Units
    Automatic Mains Failure Units
    Remote Start Units
    Manual Start Units
    Automatic Transfer Switches
    Battery Chargers
    Alternator Voltage Regulators
    Panel Measurement Units
    Earthquake Units
    Telecommunication Units
    Extension Units
    ---------------------------------------------------------------------------------------------------------------
    We have a long time experience in international sales
    and make delivery only with traceable service.
    --------------------------------------------------------------------------------------------------------------
    Other datakom products on
    www.controllers4generators.com
    --------------------------------------------------------------------------------------------------------------
    ALL CUSTOMS FEES IN COUNTRY OF DESTINATION ARE UNDER BUYER'S  RESPONSIBILITY